Variable Volume, Pressure Compensated Vane Pumps

VPVC F30/F40 SERIES

FEATURES

• VPVC series offers design engineers an opportunity to design circuits with high efficiency.
• Built-in compensator control automatically adjusts pump delivery to system volume requirements at selected pressures. System relief valve may not be needed.
• Wasted horsepower is reduced and heat generated is much less than fixed displacement pumps.

• Manual maximum flow adjustment.

 

 

 

 

 
 
 
 
 
 
  Quick Links
Model Code
Specifications
Dimensions


 
 


Model Code -
top



 

Symbol -
top



Specifications -
top



MODEL DELIVERY AT UNLOADING LPM(GPM) PRESSURE ADJ . RANGE BAR (PSI) SPEED OF ROTATION  MAX. SET PRESSURE BAR (PSI) WEIGHT
KGS (LBS)
  1800 RPM 1500 RPM 1200 RPM MAX.  MIN.  
VPVC-F30-A1-**-N       8-20 (110-290)   20 (284)  
VPVC-F30-A2-**-N 30 25 20 15-35 (200-500)     35 (500) 9
VPVC-F30-A3-**-N (7.93) (6.6) (5.3) 30-70 (430-1000) 1800 800 70 (1000) (20)
VPVC-F40-A1-**-N       8-20 (110-290)     20 (284)  
VPVC-F40-A2-**-N 40 35 28 15-35 (200-500)     35 (500) 9
VPVC-F40-A3-**-N (10.57) (9.25) (7.4) 30-70 (430-1000) 1800 800 70 (1000) (20)
 



Dimensions -
top

VPVC-F30/F40-A-**-N FLANGE SAE A                           UNIT: mm(inch) WEIGHT: 9 kgs (19.8 lbs)